Chenbro Rackmount RM42300-F2 4U Open-Bay Compact RackmountChenbro PC719 Series Powerful Micro ATX Small Form Factor ChassisChenbro Rackmount RM912 M2-R1620G 9U 50-Bay Storage Center Server ChassisChenbro Rackmount RM42200 4U Feature-advanced Industrial Server Chassis% % % Sales % % % Restposten - Odd Lot

M1Z3-6760P3V Zippy 3HE / 3U Redundant Netzteil 760Watt

86761

   Maße:
 
265x101x125(mm)
   
Dimension:
 
10.43x3.98x4.92(inch)

   Input Spezifikationen:

  
VOLTAGE: 90V ~ 264VAC 
   FREQUENCY: 47Hz ~ 63Hz 
   INPUT CURRENT: 20-10A MAX AT ANY LOW/HIGH INPUT VOLTAGE 
   INRUSH CURRENT: 60/100A @ 115/230VAC (25℃) 
   POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD 

  
Output Spezifikationen:

Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
5V 4 48 ± 5% ± 50mV 70mV
-5V 0.2 1 +5%, -10% ± 50mV 120mV
+12V 5 50 ± 6% ± 50mV 120mV
-12V 0.2 1.5 +5%, -10% ± 50mV 120mV
+3.3V 4 45 ± 5% ± 50mV 70mV
+5VSB 0.4 3.5 +5%, -6% ± 50mV 70mV
           
           
           
REMARKS:
1. THE OUTPUT POWER OF 5V AND 3.3V MAX:40A
2. EACH POWER MODULE OUTPUT MAX:420W
3. TOTAL OUTPUT POWER MAX:760W


  
Eigenschaften Features :

   *TEMPERATURE RANGE: OPERATING: 0℃ --- 40℃
    STORAGE: -20℃ --- 80℃
   *HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
   *REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
   *HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
   *DIELECTRIC WITHSTAND: INPUT / OUTPUT 3000 VAC FOR 1 SECOND
     INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
   *EFFICIENCY: 65% TYPICAL AT 115VAC FULL LOAD
   *POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
   *OVER POWER PROTECTION: 110% ~ 180%
   *OVER VOLTAGE PROTECTION: +5V -> 5.7V ~ 6.5V, 3.3V ->3.9V ~ 4.7V +12V -> 13.3V ~ 14.3V
     OVER CURRENT PROTECTION: 110% ~ 180%
   *SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
   *EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
   *SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950 
   *REMOTE ON / OFF CONTROL
   *THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE /    
     ippy ebsite

     AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
     AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.
   *3.3V REMOTE SENSING


  
Zippy Website Service & Support


   