FUM DA
Druckansicht
Kontakt
AGBs
Impressum

Chenbro PC719 Powerful Micro ATX Small Form Factor ChassisChenbro Rackmount RM42200 Cost Effective & Design-advanced 4U Server MAX POWER 350W/400W jeweils 2.000Stk. Preis auf Anfrage.Zippy R3G-6650PChenbro RM13504 1U 4-Bays Dual-System Server Chassis with Hot-Swap HDD

Zippy M1W4-6D50P

8456012

alle Bilder, all pictures...


   1350W  
   
   Server,Workstation,Storage System,Communication,Networking

340.00x426.00x42.00  (mm)
13.39x16.77x1.65  (inch)
 

VOLTAGE:  100V ~ 240VAC (WITH ± 10% TOLERANCE)
FREQUENCY: 47Hz ~ 63Hz 
INPUT CURRENT:
20-10A MAX AT ANY LOW/HIGH INPUT VOLTAGE                       
INRUSH CURRENT: 60/100A @ 115/230VAC (25℃)
POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD
 
Output Voltage Output Current Min. Output Current Max. Output Current Peak Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]

5V

6.0

84.50

 

± 5%

± 50mV

70mV

12V

6.0

90

 

± 6

± 50mV 

120mV 

-5V

0.2

1.20

 

+5%, -10%

 ± 50mV

120mV 

-12V

0.2

1.20

 

+5%, -10%

± 50mV 

120mV 

3.3V

3.5

67.5

 

± 5%

± 50mV 

70mV 

+5VSB

0.4

3.5

 

+5%, -6%

± 50mV 

70mV 


‧TEMPERATURE RANGE: OPERATING: 0℃ --- 40℃
STORAGE: -20℃ --- 80℃
‧HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
‧REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
‧HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
‧DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
‧EFFICIENCY: 67% TYPICAL AT 115VAC FULL LOAD
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
‧OVER POWER PROTECTION: 110% ~ 150%
‧OVER VOLTAGE PROTECTION: +5V ->5.7V ~ 6.5V, 3.3V -> 3.9V ~ 4.7V,+12V -> 13.3V ~ 14.3V
‧OVER CURRENT PROTECTION: 110% ~ 180%
‧SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
‧EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
‧SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
  Zippy Homepage